OSYMEN has affirmed professional and international strategic targets, opted for international standardization of production and management.





|
OSYMEN |
Unit |
N-17 |
N-19 |
CS-1 |
N-600 |
N-14 |
B-3 |
B-3A |
| Bulk density | ||||||||
|
kg/m³ |
817 |
925 |
797 |
801 |
855 |
850 |
970 |
|
|
lb/ft³ |
51 |
58 |
50 |
50 |
53 |
53 |
61 |
|
| Loss On Ignition– (Maximum Percentage) | ||||||||
|
|
% |
5.6 |
6.8 |
3.2 |
3.8 |
4.8 |
5 |
5 |
| Coeffi cient of Thermal Expansion | ||||||||
|
|
10-6/°C |
7 |
7 |
4.7 |
6.7 |
6.6 |
6.5 |
6.5 |
|
|
10-6/°F |
3.9 |
3.9 |
2.72 |
3.72 |
3.67 |
3.61 |
3.61 |
| Maximum Service Temperature | ||||||||
|
|
°C |
1050 |
1050 |
1050 |
1050 |
1050 |
1050 |
1100 |
|
|
°F |
1922 |
1922 |
1922 |
1922 |
1922 |
1922 |
2012 |
| Continuous Service Temperature | ||||||||
|
|
°C |
850 |
850 |
850 |
850 |
850 |
850 |
1000 |
|
|
°F |
1562 |
1562 |
1562 |
1562 |
1562 |
1562 |
1832 |
| Compressive Strength | ||||||||
|
|
Mpa |
24 |
24 |
19 |
19 |
17 |
18 |
30 |
|
|
lb/in² |
3479 |
3479 |
2754 |
2754 |
2464 |
2609 |
4349 |
| Flexural Strength | ||||||||
|
|
Mpa |
8.8 |
8.8 |
7.3 |
7.5 |
8.8 |
6 |
8 |
|
|
lb/in² |
1276 |
1276 |
1058 |
1087 |
1276 |
870 |
1160 |
| Thermal Shrinkage (Linear)–24 hours @ 750°C (1382°F) | ||||||||
|
|
% |
0.38 |
0.49 |
0.05 |
0.06 |
0.4 |
0.2 |
0.1 |
| Thermal conductivity | ||||||||
|
300°C |
W/(m.K) |
0.180 |
0.220 |
0.190 |
0.190 |
0.200 |
0.250 |
0.260 |
|
500°C |
W/(m.K) |
1.320 |
0.220 |
0.200 |
0.210 |
0.200 |
0.250 |
0.270 |
|
700°C |
W/(m.K) |
1.390 |
0.220 |
0.200 |
0.230 |
0.200 |
0.260 |
0.270 |
|
572°F |
BTU/(ft²×h×°F/in) |
1.249 |
1.526 |
1.318 |
1.318 |
1.388 |
1.735 |
1.804 |
|
932°F |
BTU/(ft²×h×°F/in) |
9.158 |
1.526 |
1.388 |
1.457 |
1.388 |
1.735 |
1.873 |
|
1292°F |
BTU/(ft²×h×°F/in) |
9.644 |
1.526 |
1.388 |
1.596 |
1.388 |
1.804 |
1.873 |